Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Low-temperature volume reduction rate evaluation quantifies the degree to which a material's volume shrinks when exposed to sub-zero environments, providing critical data for sealing integrity and dimensional stability in cold service conditions. This test is essential for rubber compounds, thermoplastics, foams, and finished sealing products used in automotive, aerospace, energy, refrigeration, and industrial applications. Our accredited laboratory delivers accurate volume reduction data across an extensive temperature range to support material selection, product qualification, and failure analysis.

Technical Overview

The low-temperature volume reduction rate expresses, as a percentage, the decrease in specimen volume that occurs when a material is cooled from a reference temperature (typically 23 °C standard laboratory conditions) to a specified low temperature. All polymeric materials contract as temperature drops due to reduced molecular mobility and decreased free volume between polymer chains; however, the magnitude of contraction differs significantly among materials and is often amplified near the glass transition region. For sealing elements such as O-rings, gaskets, and diaphragms, excessive volume loss at low temperature reduces contact pressure against mating surfaces, creating potential leak paths and functional failure even before the material becomes brittle or cracks.

Evaluating volume reduction behavior is therefore a fundamental step in material selection, seal design (including squeeze and gland fill compensation), and quality control for components intended for cold climates, high altitudes, refrigeration systems, and cryogenic service. The test result is commonly reported together with complementary low-temperature parameters such as the glass transition temperature, brittleness point, temperature retraction (TR) values, and the coefficient of linear thermal expansion, forming a complete low-temperature performance profile of the material.

  • Quantifies thermal shrinkage relevant to sealing force and dimensional stability
  • Reveals material behavior near the glass transition region
  • Supports comparison of candidate compounds for cold-environment service
  • Complements TR testing, brittleness testing, and compression set evaluation

Testing Samples

Rubber Vulcanizates and Compounds

Cured sheet stock or standard test pieces of NBR, HNBR, FKM, EPDM, silicone (VMQ), fluorosilicone (FVMQ), chloroprene rubber (CR), natural rubber (NR), and specialty low-temperature elastomers. Compounded materials are evaluated to compare formulations before production release.

Thermoplastic Elastomers and Engineering Plastics

Specimens of TPE, TPV, TPU, polyolefins, polyamides, and other polymers used in seals, boots, bellows, and cold-climate components, where low-temperature shrinkage affects fit, clearance, and assembly integrity.

Foam and Cellular Materials

Closed-cell and open-cell foams used in thermal insulation, gasketing, and sealing, for which volume change at low temperature influences compression behavior, recovery, and insulation performance.

Finished Sealing Products

O-rings, radial shaft seal lips, door and window weatherstrips, gaskets, diaphragms, hose sections, and cable insulation and jacketing can be tested in their as-supplied condition to verify real-world cold-environment performance.

Testing Items

The evaluation can be tailored to the intended service environment. Typical test parameters include:

  • Volume reduction rate at specified low temperatures, for example −10 °C, −25 °C, −40 °C, −55 °C, and −70 °C
  • Linear dimensional change in length, width, and thickness directions at low temperature
  • Density change between the reference and test temperatures
  • Volume–temperature profiles generated from stepped cooling programs
  • Recovery behavior, measured as the volume regain after return to ambient temperature
  • Comparative ranking of multiple candidate materials under identical conditions

Testing Methods

Specimens are first conditioned at the reference temperature until thermal and dimensional equilibrium is reached, and their initial volume is determined. The specimens are then transferred to a precision environmental chamber or cryogenic bath set to the specified test temperature, held for a conditioning period sufficient to ensure complete thermal equilibration through the specimen cross-section, and measured again. Volume reduction is calculated and reported as a percentage.

Dimensional Measurement Method

The length, width, and thickness of the specimen are measured at the reference temperature and again at the test temperature using calibrated micrometers, optical comparators, or laser measurement systems, with the measuring stage or fixture maintained at the test temperature. Volume is computed from the dimensions, which is particularly suitable for rectangular test pieces and finished parts.

Hydrostatic (Archimedes) Method

Volume is determined by immersion weighing in a temperature-controlled liquid in accordance with density and volume determination practices such as ISO 2781 and ASTM D297. This approach is well suited to irregularly shaped specimens and O-rings, and it can be performed with an immersion medium held at the low test temperature.

Calculation of Volume Reduction Rate

The volume reduction rate is calculated as: Volume Reduction Rate (%) = (V0 − VT) / V0 × 100, where V0 is the specimen volume at the reference temperature and VT is the volume at the specified low temperature. A larger positive value indicates greater shrinkage and a higher risk of seal force loss in cold service.

Complementary Low-Temperature Testing

Temperature retraction (TR10/TR50/TR70) testing per ISO 2921, ASTM D1329, and GB/T 7758, low-temperature flexibility and brittleness testing, and low-temperature compression set testing are frequently performed alongside volume reduction evaluation to build a complete picture of cold-temperature performance.

Applications

Low-temperature volume reduction rate evaluation is applied across industries in which components must maintain sealing and dimensional performance in cold environments:

  • Automotive: door and window seals, powertrain seals, fuel system components, and EV battery pack sealing for vehicles operating in sub-zero climates
  • Aerospace: seals and elastomeric components exposed to high-altitude cold soak and low-temperature fuel and hydraulic environments
  • Oil and gas: downhole and surface equipment seals for arctic and offshore operations
  • Rail transit: door seals, gangway bellows, and windshield seals for rolling stock in cold regions
  • Refrigeration and HVAC: gaskets, insulation foams, and flexible connections in refrigeration and cryogenic systems
  • Industrial and consumer products: outdoor enclosures, appliance door gaskets, and cold-chain packaging materials
  • Research and development: formulation screening, accelerated material qualification, and root-cause analysis of cold-environment seal failures

FAQ

What temperature range can be evaluated?

Standard environmental chambers cover the range from approximately −70 °C to +150 °C. Tests requiring lower temperatures, for example down to −196 °C using liquid nitrogen-cooled systems, can be arranged for specialty and cryogenic applications.

How long must specimens be conditioned at the low temperature?

Conditioning time depends on specimen thickness and thermal properties. As a general practice, specimens are held at the test temperature for a minimum of 30 minutes after the specimen core reaches equilibrium, with longer holds specified for thick sections to guarantee full thermal stabilization before measurement.

What specimen forms can be tested?

Standard cured test pieces, sheets, cut specimens, and finished products such as O-rings, gaskets, and seal profiles can all be evaluated. Testing finished parts directly provides the most realistic assessment of end-use performance.

What level of volume reduction is acceptable?

There is no universal pass/fail limit; acceptability depends on the seal design, initial squeeze, gland fill, and required sealing margin. Results are most meaningful when compared against design allowances or when used to rank candidate materials against one another under identical test conditions.

How does this test differ from TR or brittleness testing?

TR testing measures the temperature at which a stretched specimen retracts as it warms, indicating elasticity recovery, while brittleness testing identifies the temperature at which impact cracking occurs. Volume reduction evaluation directly quantifies dimensional shrinkage, making it the most relevant parameter when assessing potential loss of sealing contact pressure in the cold.

What does a typical test report include?

The report documents specimen identification, test temperature and conditioning details, measurement method, individual and mean volume values, calculated volume reduction rates, and relevant observations such as cracking, distortion, or incomplete recovery after rewarming.